Abstract

To promote prefabricated segmental bridges in regions of moderate or high seismicity, stainless energy dissipation bars (ED bars) are used continuously across the column segment critical joints to increase the hysteretic energy dissipation. However, the bond response and the design development length of the anchored ED bars were not well understood for hollow thin-wall segmental bridge columns. In this paper, an experimental program was conducted to investigate the influence of bar embedment length and ratio of duct diameter to bar diameter on monotonic bond-slip response of stainless ED bars. Phenomenological nonlinear bond-slip and end-slip models were developed to simulate the loaded bar end force-displacement relationship. The results of the experimental study were used to establish preliminary design equations for A706 and stainless Talley S24100.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.