Abstract
The increasing embrace of the low-carbon and environmentally sustainable construction approach has opened exciting opportunities for using environmentally friendly geopolymer based ultra-high-performance concrete (G-UHPC) in engineering structures, drawing significant attention to its performance. Seismic performance is a crucial factor in structural design, and it is greatly affected by the bond behavior between steel bar and concrete. As a result, a thorough understanding of the bond behavior of steel bars to G-UHPC provides essentially theoretical support for the structural design and nonlinear finite element analysis of G-UHPC structures, which is vital for their widespread implementation in earthquake engineering. This study tested 54 specimens from 18 groups to examine the bond performance of G-UHPC and steel bars under cyclic loading. The influence of concrete and steel bar types, protective layer thickness, bond length, and steel fiber on critical bond performance indicators were evaluated, and the bond stress-slip hysteretic and skeleton curves were analyzed. Subsequently, based on the experimental data, a constitutive model was proposed to predict the bond stress-slip relationship of steel bars and G-UHPC under cyclic loading. The results indicated that the steel bars exhibited superior bond performance with G-UHPC as compared to NSC. The bond and residual strength between steel rebars and G-UHPC was approximately 1.73 times and 3 times greater, respectively, in comparison with that between NSC and steel rebars. Increasing the strength of steel bars only resulted in a limited 2 % improvement in bond strength. The steel bar diameter, protective layer thickness, bond length, and the dosage and length of steel fibers in G-UHPC significantly influenced the bond performance. The addition of irregular-shaped steel fibers to G-UHPC has demonstrated potential in improving energy consumption, with the most remarkable enhancement observed for the inclusion of twisted steel fibers. Specifically, the incorporation of twisted steel fibers signally enhanced the energy consumption to approximately 1.3 times the energy dissipation as compared to straight steel fibers with the same dosage and aspect ratio. In addition, the accuracy of the proposed constitutive model has been validated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.