Abstract
The external bonds of carbon fiber reinforced polymers (CFRP) used to strengthen structures are known to be vulnerable to delamination. To prevent FRP delamination and efficiently strengthen structures, post-tension CFRP rods are installed for near-surface-mounted (NSM) strengthening. For post-tensioning, grouted anchorage systems have been applied to the NSM strengthening technique. The bond behavior between the CFRP rods and the filler in the anchorage for the post-tension rods should be investigated. This study evaluates the behavior and failure characteristics of bond-type anchorage systems based on the results of 40 pullout tests with different mortar fillers and diameters of the anchorage sleeve. The optimum mortar filler strength and sleeve diameters have been proposed to ensure proper bond behavior in NSM anchorage systems.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.