Abstract

This paper presents the second part of a study on bond. It reports on the influence of several parameters on bond in splices. The parameters covered are concrete strength, splice length, concrete cover, ratios between side cover, bottom cover, and the spacing between the spliced bars, rib face angle of the reinforcing bar, and admixtures in the concrete mix. The study was conducted in two stages. In the first stage, an analytical equation was developed to calculate the bond strength of splices in normal strength concrete. The mean value of test/calculated bond strength for the proposed equation is 1.007 with a standard deviation of 0.084. These values indicate a significant improvement in the calculation of the bond strength when compared with other proposed equations. The second stage of the research involved tests on 22 beams made of high-strength concrete (HSC). In each beam, the tensile steel was spliced in the constant moment zone. The test strengths are compared with the calculated values. Good correlation between calculated and test strengths of splices in the case of HSC is found.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.