Abstract

The bond behavior of reinforcement and low-activated concrete (LAC) was investigated in this study. The acoustic emission monitoring was also engaged while the specimen being loaded to figure out the inside fracture. Static loading and dynamic loading were applied for both of the LAC and normal concrete in the pull-out tests. The upper load was applied starting from 30% of the static ultimate load Pu with a 10% increment until the failure. The loading frequencies for the test were 0.5 Hz、1.0 Hz and 2.0 Hz. The bond stiffness after each stage of dynamical loads was examined. Test results reveal that the LAC performs higher compressive strength than normal concrete for a given W/C ratio. But, the bond strength of LAC seems not promotes correspondingly. It may be attributed to the conversion effect of high alumina contained in LAC, which leads to more voids inside the concrete.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.