Abstract

Diabetes is commonly treated with glucagon-like peptide-1 receptor (GLP-1R) agonists including liraglutide and others. However, liraglutide was found to raise plasma glucose levels in normal rats. The current study aims to determine how liraglutide causes this contentious condition in rats, both normal and diabetic. An adrenalectomy was performed to investigate the relationship between steroid hormone and liraglutide. To investigate the effect of central liraglutide infusion on blood glucose in rats, rats were intracerebroventricularly administrated with liraglutide with or without HPA axis inhibitors such as berberine and dexamethasone. The results showed that a single injection of liraglutide caused a temporary increase in blood glucose in healthy rats. Another GLP-1R agonist, Exendin-4 (Ex-4), increased blood sugar in a manner similar to that of liraglutide. The effects of liraglutide were also blocked by guanethidine pretreatment and vanished in normal rats with adrenalectomy. Additionally, central infusion of liraglutide via intracerebroventricular (icv) injection into normal rats also causes a temporary increase in blood glucose that was blocked by GLP-1R antagonists or the inhibitors such as berberine and dexamethasone. Similarly, central liraglutide treatment causes temporary increases in plasma glucose, adrenocorticotropic hormone (ACTH), and cortisol levels, which were reversed by inhibitors for the hypothalamic-pituitary-adrenal (HPA) axis. In normal rats, the temporary glucose-increasing effect of liraglutide was gradually eliminated during consecutive daily treatments, indicating tolerance formation. Additionally, liraglutide and Ex-4 cross-tolerance was also discovered in normal rats. Liraglutide was more effective in diabetic rats than in normal rats in activating GLP-1R gene expression in the isolated adrenal gland. Interestingly, the effect of liraglutide on glycemic control varied depending on whether the rats were diabetic or not. In normal rats, bolus injection of liraglutide, such as Ex-4, may stimulate the HPA axis, resulting in hyperglycemia. The cross-tolerance of liraglutide and Ex-4 provided a novel perspective on GLP-1R activation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.