Abstract
Boiling heat transfer characteristics in liquid-liquid direct contact parallel flow of immiscible liquids were investigated. The effect of operating conditions and column specifications on the UA factor of heat transfer was determined and the following empirical correlation is proposed : St=k1+k2M*aH*bZ*cN*d for conditions where subcooling is constant. The Stanton number for heat transfer to the dispersed phase is shown to correlate with the product of the Jacob number and the Prandtl number, H*. Comparison of heat transfer-flow pattern and the correlation equation of heat transfer showed good agreement within a range of ±30%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.