Abstract
Bobbin coil and bobbin-type Hall sensor arrays are proposed as an alternative for crack inspection inside a small-bore piping system. The cracks can be imaged at high speed without using a scanner since the electromagnetic (EM) field is distorted by the cracks. An array of 32 × 32 Hall sensors with 0.78 mm spatial resolution was set in a cylinder with diameter of 15 mm and length of 24.96 mm. A bobbin coil operating at 5 kHz of alternating current was positioned inside of a piping system and the sensor array outside the cylinder. Distorted EM fields around outside diameter stress corrosion cracking was imaged at 1 frame/s.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.