Abstract

The aim of the study was to assess plasma volume (PV) and red cell volume (RCV) in preterm infants with a liquid chromatographic hemoglobin subtype method (HbST) based on dilution of autologous fetal hemoglobin (HbF) by donor adult hemoglobin and measurement of the amount of HbF. PV determination with the indocyanine green dye dilution technique (ICG) was used as a reference method. Eight infants, median gestational age 29.8 weeks (range 27.6–30.9 weeks) and median birth weight 1,300 g (range 1,030–1,760 g), were studied at a median age of 3.0 days (range 1–6 days). RCV was 33.6 ± 12 ml/kg measured with ICG and 32.1 ± 5.2 ml/kg with HbST. PV was 47.0 ± 18 and 40.2 ± 6.6 ml/kg, respectively. There was a close correlation between the RCVs measured with the two techniques (Pearson correlation 0.83, p < 0.05). In conclusion, HbST provides a reliable and safe determination of RCV in preterm infants.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.