Abstract

Although debate about the relationship between lead and blood pressure has focused on low environmental lead levels, industrial exposure remains a concern. We measured blood pressure and left ventricular mass (LVM) in 108 battery manufacturing workers, and calculated cumulative and historic average measures of blood lead. Diastolic pressure increased with increasing lead levels, with a significant (P = 0.04) 5 mmHg difference in mean pressure between the highest and lowest cumulative exposure levels. Diastolic pressure increased with the log of cumulative lead (P = 0.06). Both hypertension (defined as currently medicated or systolic > 160 mmHg or diastolic > 95 mmHg) and LVM increased nonsignificantly with increasing lead exposure (P-values > or = 0.17 for hypertension and > or = 0.20 for LVM). We found a small effect of blood lead on diastolic blood pressure, particularly for a cumulative measure of exposure, but no convincing evidence of associations between lead and other blood-pressure-related outcomes. Published 2001 Wiley-Liss, Inc.