Abstract

This study presents experimental results on hydrogen blister formation on powder metallurgy tungsten (PM-W) surface under low energy (<100 eV) and high ion flux (>10 21 m −2 s −1) hydrogen plasma irradiation in a divertor plasma simulator-NAGDIS-I. The tungsten samples were exposed to steady-state hydrogen plasma at various sample temperatures and fluences. Hydrogen blister formations are clearly observed on tungsten surface at the surface temperature below 950 K. The blister size is from a few 10 μm to a few 100 μm. It was found that the blister formations obviously depend on the surface temperature and the incident hydrogen ion fluence. No blisters are observed on tungsten surface at the surface temperature above 950 K even if the fluence is high enough.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.