Abstract

Objectives(1) To investigate whether a contrast-free biparametric MRI (bp-MRI) including T2-weighted images (T2W) and diffusion-weighted images (DWI) can be considered an accurate alternative to the standard multiparametric MRI (mp-MRI), consisting of T2, DWI, and dynamic contrast-enhanced (DCE) imaging for the muscle-invasiveness assessment of bladder cancer (BC), and (2) to evaluate how the diagnostic performance of differently experienced readers is affected according to the type of MRI protocol.MethodsThirty-eight patients who underwent a clinically indicated bladder mp-MRI on a 3-T scanner were prospectively enrolled. Trans-urethral resection of bladder was the gold standard. Two sets of images, set 1 (bp-MRI) and set 2 (mp-MRI), were independently reviewed by four readers. Descriptive statistics, including sensitivity and specificity, were calculated for each reader. Receiver operating characteristic (ROC) analysis was performed, and the areas under the curve (AUCs) were calculated for the bp-MRI and the standard mp-MRI. Pairwise comparison of the ROC curves was performed.ResultsThe AUCs for bp- and mp-MRI were respectively 0.91–0.92 (reader 1), 0.90 (reader 2), 0.95–0.90 (reader 3), and 0.90–0.87 (reader 4). Sensitivity was 100% for both protocols and specificity ranged between 79.31 and 89.66% and between 79.31 and 83.33% for bp-MRI and mp-MRI, respectively. No significant differences were shown between the two MRI protocols (p > 0.05). No significant differences were shown accordingly to the reader’s experience (p > 0.05).ConclusionsA bp-MRI protocol consisting of T2W and DWI has comparable diagnostic accuracy to the standard mp-MRI protocol for the detection of muscle-invasive bladder cancer. The experience of the reader does not significantly affect the diagnostic performance using VI-RADS.Key Points• The contrast-free MRI protocol shows a comparable accuracy to the standard multiparametric MRI protocol in the bladder cancer muscle-invasiveness assessment.• VI-RADS classification helps non-expert radiologists to assess the muscle-invasiveness of bladder cancer.• DCE should be carefully interpreted by less experienced readers due to inflammatory changes representing a potential pitfall.

Highlights

  • Objectives (1) To investigate whether a contrast-free biparametric MRI including T2-weighted images (T2W) and diffusion-weighted images (DWI) can be considered an accurate alternative to the standard multiparametric MRI, consisting of T2, DWI, and dynamic contrast-enhanced (DCE) imaging for the muscle-invasiveness assessment of bladder cancer (BC), and (2) to evaluate how the diagnostic performance of differently experienced readers is affected according to the type of MRI protocol

  • Vesical Imaging-Reporting and Data System (VI-RADS) classification helps non-expert radiologists to assess the muscle-invasiveness of bladder cancer

  • DCE should be carefully interpreted by less experienced readers due to inflammatory changes representing a potential pitfall

Read more

Summary

Introduction

Objectives (1) To investigate whether a contrast-free biparametric MRI (bp-MRI) including T2-weighted images (T2W) and diffusion-weighted images (DWI) can be considered an accurate alternative to the standard multiparametric MRI (mp-MRI), consisting of T2, DWI, and dynamic contrast-enhanced (DCE) imaging for the muscle-invasiveness assessment of bladder cancer (BC), and (2) to evaluate how the diagnostic performance of differently experienced readers is affected according to the type of MRI protocol. Trans-urethral resection of bladder was the gold standard. Set 1 (bp-MRI) and set 2 (mp-MRI), were independently reviewed by four readers. Descriptive statistics, including sensitivity and specificity, were calculated for each reader. Receiver operating characteristic (ROC) analysis was performed, and the areas under the curve (AUCs) were calculated for the bp-MRI and the standard mp-MRI. Pairwise comparison of the ROC curves was performed

Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.