Abstract

The direct thrombin inhibitor bivalirudin is an option for anticoagulation in patients with heparin induced thrombocytopenia (HIT) requiring cardiopulmonary bypass (CPB). There are a limited number of reports of pediatric patients in which bivalirudin has been used for anticoagulation for CPB. We present the case of an 11 year old male with acute onset heart failure secondary to idiopathic dilated cardiomyopathy that developed heparin induced thrombocytopenia with thrombosis (HITT). The patient was anticoagulated in the operating room with bivalirudin and placed on CPB for insertion of a HeartWare® Ventricular Assist Device (Heartware®). Modified techniques were utilized. This included use of the Terumo CDI 500 (Terumo Cardiovascular Systems, Inc.) in-line blood gas monitor which contains a heparin coated arterial shunt sensor. We flushed this sensor with buffered saline preoperatively and noted no significant decrease in platelet count postoperatively. The patient was successfully placed on the ventricular assist device and was subsequently listed for heart transplantation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.