Abstract

BackgroundBreast cancer is the most common cancer in women worldwide. It is responsible for about 23% of cancer in females in both developed and developing countries [1]. We aimed to assess the accuracy of contrast-enhanced spectral mammography (CESM) versus contrast-enhanced breast MRI in the evaluation of BIRADS 4 breast lesions.ResultsFifty patients were included in this study; there were 28 malignant cases and 22 benign cases; all cases were proved by histopathological result either by core biopsy or excision biopsy. CESM was found to have less sensitivity (94.1%) than MRI (100%) but CESM has higher specificity (100%) than MRI (95.5%). The accuracy of CESM was 96.4%, while the accuracy of MRI was 98.2% with no statistical significance (P value 0.827).ConclusionCESM can be used as a sensitive diagnostic tool in the detection and staging of breast cancer with higher specificity and less sensitivity as compared to contrast enhanced breast MRI.

Full Text