Abstract
We developed new methods for real time biplane integration of three-dimensional (3D) left atrial models with fluoroscopic images to assist in catheter ablation of atrial fibrillation (AF). The purpose of this study was to quantitatively assess the accuracy of 3D fluoroscopy integration and to evaluate its clinical value when used as a single navigation tool for AF ablation. Sixty patients underwent AF ablation under biplane fluoroscopic guidance after selective angiography of the four pulmonary veins. Computed tomography [CT]-based 3D models were integrated in the fluoroscopic framework using visual matching and landmark-based registration approaches. Integration accuracy was quantitatively assessed according to registration approach and different CT acquisition parameters (electrocardiogram [ECG] gating, respiratory phase). In 30 of the 60 patients (3D+ group), the integrated 3D model was used for real time 3D-augmented fluoroscopic catheter navigation, and the effects on procedural parameters and patient radiation dose were evaluated. Landmark-based registration resulted in superior 3D fluoroscopy integration accuracy compared with the visual matching approach (P <.001 for alignment error and alignment score). The effects of ECG gating and respiratory phase during CT acquisition on integration accuracy were small and clinically irrelevant. The use of 3D-augmented fluoroscopy in the 3D+ group was gauged as extremely helpful by the operator. It resulted in a significant reduction of fluoroscopy time (61 +/- 18 minutes vs. 77 +/- 26 minutes; P = .009) and a trend toward shorter procedure duration (230 +/- 67 minutes vs. 257 +/- 58 minutes; P = .06) versus conventional procedures. The systematic use of nongated cardiac CT in the 3D+ group resulted in an important reduction in total effective patient radiation dose due to CT+fluoroscopy (4 + 14 = 18 +/- 8 mSv vs.17 + 16 = 33 +/- 13 mSv; P <.001). Biplane 3D-augmented fluoroscopy can be used as a safe and accurate stand-alone method to guide AF ablation procedures. The use of nongated cardiac CT substantially reduces total patient radiation dose without a relevant reduction in integration accuracy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.