Abstract

Studies of epithelial membrane polarity have been greatly facilitated through the use of the N-hydroxysuccinimide-biotin surface labeling technique (M. Sargiacomo, M. Lisanti, L. Graeve, A. Le Bivic, and E. Rodriguez-Boulan. J. Membr. Biol. 107: 277-286, 1989). We have used this technique in studies on the sorting and targeting of ion-transporting adenosinetriphosphatase molecules in polarized epithelial cells. Through efforts to optimize this technique in our experimental system, we have encountered several experimental conditions and circumstances where biotinylation is extremely inefficient and the assessment of membrane polarity which it provides is misleading. We demonstrate that the pH and ionic strength of the biotinylation buffer can dramatically affect biotin incorporation and that protocol-dependent variations in the recovery of biotinylated proteins can result in misrepresentation of the actual apical/basolateral distribution of a protein. Conditions and protocols that may improve the sensitivity and accuracy of this technique are discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.