Abstract

Hair samples continue to be used extensively for biomonitoring of mercury (Hg) exposure. Routine methods require a bundle of 100-150 hair strands and involve chemical digestion. Recently, Hg analyzers that combine combustion, gold amalgamation, and atomic absorption spectrometry (C-GA-AAS) became commercially available. This method was shown to provide quick and sensitive measurements in solid samples such as hair. The objective of this study was to validate C-GA-AAS for measuring total Hg in single hair strands as an alternative method for Hg biomonitoring. Hair samples from 12 women with a wide range of Hg exposure were obtained from two projects conducted in Brazil and Canada. A 1:1 relationship was observed between C-GA-AAS and the established cold vapor atomic absorption spectrometry (CV-AAS) for analysis of 1-cm segments from a bundle of hair. For individual hair variability, the average relative standard deviation (RSD) of Hg between hair strands was 6.5 +/- 2.8%, thus justifying the use of single hair strand for biomonitoring. With a limit of quantification of 0.10 ng of total Hg, a single hair strand can be used to assess monthly exposure. This technique will facilitate routine biomonitoring and thus help prevent Hg poisoning among the public.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call