Abstract
BackgroundA consensus regarding the optimal approach for treating femoral neck fractures is lacking. We aimed to investigate the biomechanical outcomes of Femoral Neck System (FNS) internal fixation components in the treatment of nonanatomically reduced femoral neck fractures.MethodWe constructed two types of femoral neck fractures of the Pauwels classification with angles of 30° and 50°, and three models of anatomic reduction, positive buttress reduction and negative buttress reduction were constructed. Subgroups of 1 to 4 mm were divided according to the distance of displacement in the positive buttress reduction and negative buttress reduction models. The von Mises stress and displacements of the femur and FNS internal fixation components were measured for each fracture group under 2100-N axial loads.ResultsWhen the Pauwels angle was 30°, the positive 1-mm and 2-mm models had lower FNS stress than the negative buttress model. The positive 3- and 4-mm models showed FNS stress similar to that of the negative buttress model. But the four positive buttress models had similar stresses on the femur as the negative buttress model. When the Pauwels angle was 50°, the four positive buttress models had higher FNS stress than the negative buttress model. Three positive buttress models (2 mm, 3 and 4 mm) resulted in lower stress of the femur than the negative buttress model, though the 1-mm model did not. When the Pauwels angle was 30°, the positive buttress model had a lower displacement of the FNS than the negative buttress model and a similar displacement of the femur with the negative buttress model. When the Pauwels angle was 50°, the positive buttress model had a higher displacement of the FNS and femur than the negative buttress model. Our study also showed that the von Mises stress and displacement of the internal fixation and the femur increased as the fracture angle increased.ConclusionFrom the perspectiveof biomechanics, when the Pauwels angle was 30°, positive buttress was morestable to negative buttress. However, when the Pauwels angle was 50°, this advantage weakens.In our opinion, the clinical efficacy of FNS internal fixation with positivebuttress may be related to the fracture angle, neck-shaft angle and alignmentin the lateral view. This result needs verification in further clinicalstudies.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.