Abstract

Clothing fit and pressure comfort play important role in clothing comfort, especially in medical body sculpting clothing (MBSC). In the present study, different body movements (forward bending, side bending, and twisting) were adopted to simulate and investigate the biomechanical stress distribution of the human body with three kinds of porosity inelastic MBSCs through the finite element analysis method. The elastic modulus of the investigated MBSCs was also measured by means of tensile testing. Analytical results showed that in the compression region during body movements, the investigated inelastic MBSCs endured less compression stress, and most of the stress was transmitted to the human body. Moreover, the stresses on the body surface were decreased with the porosity increasing. However, most of the von Mises stresses on the human body were in the desired pressure comfort range. Therefore, these results could provide potential information in the modification of MBSC for medical applications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call