Abstract

The influence of cryopreservation of cancellous bone at different temperatures and different storage periods was investigated for mechanical changes. Standardized cancellous cylinders (50 x 25 mm) were stored at -20 degrees C or -80 degrees C for 6 or 12 months, respectively, or for 2 years and then subjected to a screw pull-out test. No significant differences were found among the various storage temperatures and periods investigated. We conclude that different cryopreservation temperatures do not have any influence on the mechanical properties of cancellous bone. Also, storage duration up to 2 years has no effects on the mechanical strength of the bone.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.