Abstract

In vitro biomechanical investigation with nondestructive and destructive testing in a human cadaveric model simulating a wide postlaminectomy condition. To determine the relative stability conferred by a posterior cervical spinal rod system and posterior cervical plating. Posterior cervical plate fixation has been shown to be biomechanically superior to wiring techniques, but lateral mass screws may injure neurovascular structures or facet joints if they are inserted improperly. A cervical rod system has been developed to enhance the safety of lateral mass instrumentation. The cervical spines of 12 cadavers underwent biomechanical testing. After completion of the nondestructive intact testing, a wide laminectomy with subtotal facetectomies from C4 to C6 was performed. The specimens in two subgroups (group A, cervical spine rods with unicortical fixation, and group B, reconstruction plates with bicortical fixation) were tested in flexion, lateral bending, and torsion. Finally, destructive testing in flexion was performed. Stiffness, neutral zone, failure moment, energy to failure, and mechanism of failure were determined for each specimen. The data were analyzed using paired t tests and ANOVA. Group B had a greater mean screw torque value. The instrumented constructs had a greater stiffness ratio (instrumented/intact) than the intact specimens in flexion, lateral bending, and torsional testing. Group A had a significantly greater flexural stiffness than Group B. Neutral zone ratio values were significantly lower during flexural testing for the cervical rod construct. Destructive testing resulted in significantly greater failure moment and energy-to-failure values for group A. In the cervical rod construct, failure occurred primarily by superior screw loosening with pull-out from the lateral mass. Reconstruction plates consistently failed with fracture of the lateral mass and superior screw loosening. Significantly greater stability was noted in the cervical rod construct during nondestructive and destructive flexural testing.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.