Abstract
Background: Abnormal glenoid version is a risk factor for shoulder instability. However, the degree to which the variance in version (both anteversion and retroversion) affects one’s predisposition for instability is not well understood. Purpose: To determine the influence of glenoid version on anterior shoulder joint stability and to determine if the direction of the humeral head dislocation is a stimulus for the development of Hill-Sachs lesions. Study Design: Controlled laboratory study. Methods: Ten human cadaveric shoulders (mean age, 59.4 ± 4.3 years) were tested using a custom shoulder dislocation device placed in a position of apprehension (90° of abduction with 90° of external rotation). Glenoid version was adjusted in 5° increments for a total of 6 version angles tested: +10°, +5°, 0°, −5°, −10°, and −15° (anteversion angles are positive, and retroversion angles are negative). Two humeral dislocation directions were tested. The first direction was true anterior through the anterior-posterior glenoid axis. The second dislocation direction was 35° inferior from the anterior-posterior glenoid axis based on the deforming force role of the pectoralis major. The force and energy to dislocate were recorded. Results: Changes in glenoid version manifested a linear effect on the dislocation force. The energy to dislocate increased as a second-order polynomial as a function of increasing glenoid retroversion. Glenoid version of +10° anteversion and −15° retroversion was highly unstable, resulting in spontaneous dislocation in one-quarter (10/40) and one-half (25/40) of the specimens anteriorly and posteriorly, respectively, in the absence of an applied dislocation force. The greater tuberosity was observed to engage with the anterior glenoid rim, consistent with Hill-Sachs lesions, 40% more frequently when the dislocation direction was true anterior compared with 35° inferior from the anterior-posterior glenoid axis. The engagement of the greater tuberosity caused an increase in the energy required to dislocate. Conclusion: Glenoid version has a direct effect on the force required for a dislocation. An anterior-inferior dislocation direction requires less energy for a dislocation and results in a lower risk of the development of a Hill-Sachs lesion than a direct anterior dislocation direction. Clinical Relevance: Consideration should be given to glenoid version when choosing a surgical treatment option for anterior shoulder instability.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.