Abstract

Background contextMultilevel corpectomy, with or without anterior instrumentation, has been associated with both graft and anterior screw-plate complications. The addition of posterior instrumentation after anterior fixation has been shown to increase the overall stiffness of fused segments and decrease the likelihood of instrumentation failure. Little biomechanical information exists for providing guidance in the selection of an appropriate instrumentation technique after a multilevel cervical corpectomy. Clinical studies have also been inconclusive in choosing an optimum fixation strategy. PurposeTo test the hypothesis that combined anterior-posterior fixation would lower the stresses on the bone-screw interfaces observed after an isolated anterior fixation and on the graft–end plate interfaces observed after an isolated posterior fixation. Study designA finite element (FE) analysis of a C4–C7 corpectomy fusion with three different fixation techniques: anterior, posterior, and combined anterior-posterior. MethodsA previously validated three-dimensional FE model of an intact C3–T1 segment was used. From this intact model, three additional instrumentation models were constructed using anterior (rigid screw-plate), posterior (rigid screw-rod), and combined anterior-posterior fixation techniques following a C4–C7 corpectomy fusion. Construct stability at the cephalad and caudal levels of the corpectomy was assessed. ResultsBiomechanical comparisons between these instrumentation techniques show the least amount of construct motion in the combined anterior-posterior instrumentation model. The use of both anterior and posterior fixation shields the graft–end plate and screw-bone interfaces from peak stresses as compared with an isolated anterior or an isolated posterior fixation, thereby supporting the hypothesis of this study. ConclusionsA combined fixation technique should be balanced against increased operating room time and surgery costs because of dual anterior and posterior fixation and the increased risk of long anterior plating, such as dysphasia, plate or screw dislodgement, or migration. Our study suggests that the use of posterior fixation, whether alone or in combination with anterior fixation, infers comparable stability. Further studies are warranted to identify whether the current findings are consistent with other biomechanical studies.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.