Abstract

Trans-femoral amputees are needed to regain moving pattern by refined rehabilitation program using load conditions on a prosthetic limb with the artificial knee joint. On the other hand, understanding loads applied on a prosthetic limb is important for biomechanical consideration of trans-femoral amputees. However, conventional prosthetic gait training systems cannot measure long continuous walking motions under an outdoor environment. In this paper, loads applied on the intermediate part of trans-femoral prosthesis are measured by the prosthetic gait training system for the unrestrained gait measurement. As a result of the experiments, the patterns of moments about the medio-lateral axis along a gait cycle are remarkably different among the six activities. Finally, the effectiveness of the developed prosthetic gait training system is validated and the understanding of biomechanics in trans-femoral prosthesis during gait is increased. Loading data will be useful to refine the rehabilitation protocol for trans-femoral amputees with a prosthetic limb.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.