Abstract

To compare the mechanical properties of suture tape and orthopedic wire cerclage in an ex vivo canine median sternotomy model. Ex vivo. Twelve large-breed canine cadaveric sternums. Median sternotomies were performed, leaving the manubrium intact. The specimens were randomly assigned to group W (20-gauge stainless steel orthopedic wire cerclage in a figure-of-eight pattern) or group ST (suture tape in a figure-of-eight pattern). Each specimen was laterally distracted until failure using an electrodynamic materials-testing system. No differences were observed for displacement, yield load, maximum load, implant failure between the groups. The orthopedic wire construct was stiffer than the suture tape construct. Suture tape was biomechanically similar to orthopedic wire cerclage for sternotomy closure in dogs, although wire constructs were stiffer. Suture tape may represent an alternative to cerclage wire for sternotomy closure in dogs. Additional studies evaluating its clinical use are needed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.