Abstract

To verify corneal biomechanical changes, poststromal augmentation using myopic small-incision lenticule extraction's (SMILEs) lenticules in advanced keratoconus (KCN) through Corvis ST (Oculus, Wetzlar, Germany). A clinical trial enrolled 22 advanced KCN patients. We implanted lenticules exceeding 100 μ according to a nomogram and evaluated biomechanical factors through Corvis ST at 3-, 6-, and 24-month postimplantation. We examined parameters during the first applanation (A1), second applanation (A2), highest concavity (HC)/max concavity events, and Vinciguerra screening parameters, as recently established criteria derived from the ideal blend of diverse biomechanical and ocular factors and formulated through the application of logistic regression. Regression analyses explored relationships with age, mean keratometry value, thickness, sphere, cylinder, and best-corrected visual acuity. Patients were well matched for age, intraocular pressure, and central corneal thickness (CCT). The mean spherical equivalent decreased from -13.48 ± 2.86 Diopters (D) to -8.59 ± 2.17 D (P < 0.007), and mean keratometry decreased from 54.68 ± 2.77 D to 51.95 ± 2.21 D (P < 0.006). Significant increases were observed in HC time (HCT), Radius-central curvature radius at the HC state-, peak distance (PD) during HC state, CCT, first applanation time, and stiffness parameter (A1T and SP-A1), whereas HC deformation amplitude, maximum deformation amplitude ratio at 2 mm, Corvis Biomechanical Index (CBI), integrated radius (IR), second applanation deformation amplitude (A2DA), first applanation velocity and deflection amplitude (A1V and A1DeflA) significantly decreased postlenticule implantation. Multivariable regression revealed age positively correlated with SP-A1 (P = 0.003) and negatively with HC delta Arc length (P = 0.007). Mean K positively correlated with CCT (P = 0.05) and negatively with CBI (P = 0.032). Best-corrected visual acuity positively correlated with HCT (P = 0.044), and the cylinder positively correlated with PD (P = 0.05) and CCT (P = 0.05) whereas negatively with IR (P = 0.025). Stromal augmentation using myopic SMILE lenticules induces significant corneal biomechanical changes in KCN.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.