Abstract

BackgroundMany types of titanium plates were used to treat subcondylar fracture clinically. However, the efficacy of fixation in different implant positions and lengths of the bone plate has not been thoroughly investigated. Therefore, the primary purpose of this study was to use finite element analysis (FEA) to analyze the biomechanical effects of subcondylar fracture fixation with miniplates at different positions and lengths so that clinicians were able to find a better strategy of fixation to improve the efficacy and outcome of treatment.MethodsThe CAD software was used to combine the mandible, miniplate, and screw to create seven different FEA computer models. These models with subcondylar fracture were fixed with miniplates at different positions and of different lengths. The right unilateral molar clench occlusal mode was applied. The observational indicators were the reaction force at the temporomandibular joint, von Mises stress of the mandibular bone, miniplate and screw, and the sliding distance on the oblique surface of the fracture site at the mandibular condyle.ResultsThe results showed the efficacy of fixation was better when two miniplates were used comparing to only one miniplates. Moreover, using longer miniplates for fixation had better results than the short one. Furthermore, fixing miniplates at the posterior portion of subcondylar region would have a better fixation efficacy and less sliding distance (5.46–5.76 μm) than fixing at the anterolateral surface of subcondylar region (6.10–7.00 μm).ConclusionMiniplate fixation, which was placed closer to the posterior margin, could effectively reduce the amount of sliding distance in the fracture site, thereby achieving greater stability. Furthermore, fixation efficiency was improved when an additional miniplate was placed at the anterior margin. Our study suggested that the placement of miniplates at the posterior surface and the additional plate could effectively improve stability.

Highlights

  • IntroductionThe efficacy of fixation in different implant positions and lengths of the bone plate has not been thoroughly investigated

  • Many types of titanium plates were used to treat subcondylar fracture clinically

  • The distribution of the von Mises stress in the overall structure, reaction force at the left and right fixed ends of the temporomandibular joint (TMJ), and sliding distance on the oblique surface of the fracture site at the mandibular condyle were obtained using the finite element analysis (FEA)

Read more

Summary

Introduction

The efficacy of fixation in different implant positions and lengths of the bone plate has not been thoroughly investigated. There‐ fore, the primary purpose of this study was to use finite element analysis (FEA) to analyze the biomechanical effects of subcondylar fracture fixation with miniplates at different positions and lengths so that clinicians were able to find a better strategy of fixation to improve the efficacy and outcome of treatment. In open reduction and internal fixation, an endoscope is used to enter the subcondylar fracture region via retromolar approach intraorally to reduce the fracture. Another way to perform open reduction and internal fixation is via extraoral approach to reduce them. Patients, who underwent open reduction and internal fixation, exhibited better surgical outcomes, including larger maximum mouth opening and better intermaxillary relationship [5,6,7]

Objectives
Methods
Results
Discussion
Conclusion