Abstract

BackgroundIn revision total knee arthroplasty, addressing significant bone loss often involves the use of cemented or press-fit stems to ensure implant stability and long-term fixation. A possible alternative to stem was recently introduced utilizing custom-made porous metaphyseal cones, designed to reconstruct the missing tibial and femoral geometries. Early clinical and radiological assessments have shown promising results. The objective of this research was to biomechanically evaluate the performances of these custom-made cones.MethodsThe biomechanical study was conducted using a validated finite element model. The bone geometries of a patient (selected for their history of four knee revisions due to infection and periprosthetic fractures, followed by a successful treatment with custom-made 3D-printed metaphyseal cones) were employed for the study. On these bone models, different revision scenarios were simulated and examined biomechanically: (A) custom-made cementless metaphyseal cones; (B) cemented stems; (C) press-fit stems; (D) distal femoral reconstruction with press-fit stem. All the models were analyzed at 0 °and 90 °of flexion, under physiological load conditions simulating daily activities; stress distribution, average Von-Mises stresses and risk of fracture were then analyzed and compared among configurations.ResultsThe use of custom-made 3D-printed cones exhibited the most favorable stress distribution in both femoral and tibial bones. Tibial bone stress was evenly distributed in custom-made cone configurations, while stress concentration was observed in distal regions for the other scenarios. Additionally, custom-made cones displayed overall homogeneity and lower stress levels, potentially contributing to limit pain. Symmetrical stress distribution was observed between the lateral and medial proximal tibia in custom-made cone models, whereas other scenarios exhibited uneven stress, particularly in the anterior tibial bone.ConclusionsThe biomechanical analysis of porous custom-made metaphyseal cones in re-revision arthroplasties is in agreement with the positive clinical and radiological outcomes. These findings provide valuable insights into the potential benefits of using custom-made cones, which offer more uniform stress distribution and may contribute to improve patient outcomes in revision TKA procedures. Further studies in this direction are warranted to validate these biomechanical findings.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.