Abstract

PurposeThe traditional strategy for fixing intra-articular distal humerus fractures is double plating placed in an orthogonal or parallel configuration, based on posterior approach. With a combined medial and lateral approach, a novel configuration of plating (combined anteromedial and anterolateral plating) has been used. In this study, we investigated the biomechanical properties of the novel plating by comparing it with orthogonal plating.MethodsBased on the 3D morphology of a healthy subject’s humerus, the models of simple intra-articular distal humerus fractures were simulated. Two configurations of plating were applied to fix the models: the novel plating (with one plate anteromedially and the other anterolaterally on distal humerus), and orthogonal plating. Stresses, displacement, and stiffness were simulated and calculated under the conditions of axial compression, rotation torsion, bending torsion, and valgus torsion by using finite element analysis.ResultsIn all the conditions, the maximal von Mises stresses of the novel plating are similar to those of orthogonal plating, and the patterns of stress distribution are similar between these two configurations. However, the impact of high stresses was weaker on the novel plating. The maximal displacement of the novel plating is smaller than that of orthogonal plating. The stiffness of the novel plating is superior to that of orthogonal plating, with the improvements of 19.4%, 122.7%, 25.0%, and 54.2% in axial compression, rotation torsion, bending torsion, and valgus torsion, respectively.ConclusionsThe novel plating is stronger than orthogonal plating without increasing stress magnitude when fixing simple intra-articular distal humerus fractures, which makes it a feasible alternative. Further biomechanical and clinical studies are needed for a decisive conclusion.

Highlights

  • The intra-articular distal humerus fractures have always been challenging for orthopedic surgeons

  • We proposed a so-called combined medial and lateral approach for treating intra-articular distal humerus fractures, and a novel configuration with a plate anteromedially and the other anterolaterally came into being (Fig. 1) [15, 16]

  • This novel plating locates on the anterior aspect of the distal humerus, which deserves to be further studied

Read more

Summary

Introduction

The intra-articular distal humerus fractures have always been challenging for orthopedic surgeons. The prognosis of total elbow arthroplasty are proving to be less predictable than those described for the hip and the knee [1, 2], and internal fixation technique is still the preferred surgical option for patients who are young, active, and in want of quality motor function [3, 4]. The configuration of internal fixation is dictated by sorts of factors, and surgical approach is an essential one of them. We proposed a so-called combined medial and lateral approach for treating intra-articular distal humerus fractures, and a novel configuration with a plate anteromedially and the other anterolaterally came into being (Fig. 1) [15, 16]. This novel plating locates on the anterior aspect of the distal humerus, which deserves to be further studied

Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.