Abstract
BackgroundPhysiologically based kinetic models facilitate the safety assessment of inhaled engineered nanomaterials (ENMs). To develop these models, high quality datasets on well-characterized ENMs are needed. However, there are at present, several data gaps in the systemic availability of poorly soluble particles after inhalation. The aim of the present study was therefore to acquire two comparable datasets to parametrize a physiologically-based kinetic model.MethodRats were exposed to cerium dioxide (CeO2, 28.4 ± 10.4 nm) and titanium dioxide (TiO2, 21.6 ± 1.5 nm) ENMs in a single nose-only exposure to 20 mg/m3 or a repeated exposure of 2 × 5 days to 5 mg/m3. Different dose levels were obtained by varying the exposure time for 30 min, 2 or 6 h per day. The content of cerium or titanium in three compartments of the lung (tissue, epithelial lining fluid and freely moving cells), mediastinal lymph nodes, liver, spleen, kidney, blood and excreta was measured by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) at various time points post-exposure. As biodistribution is best studied at sub-toxic dose levels, lactate dehydrogenase (LDH), total protein, total cell numbers and differential cell counts were determined in bronchoalveolar lavage fluid (BALF).ResultsAlthough similar lung deposited doses were obtained for both materials, exposure to CeO2 induced persistent inflammation indicated by neutrophil granulocytes influx and exhibited an increased lung elimination half-time, while exposure to TiO2 did not. The lavaged lung tissue contained the highest metal concentration compared to the lavage fluid and cells in the lavage fluid for both materials. Increased cerium concentrations above control levels in secondary organs such as lymph nodes, liver, spleen, kidney, urine and faeces were detected, while for titanium this was found in lymph nodes and liver after repeated exposure and in blood and faeces after a single exposure. Conclusion: We have provided insight in the distribution kinetics of these two ENMs based on experimental data and modelling. The study design allows extrapolation at different dose-levels and study durations. Despite equal dose levels of both ENMs, we observed different distribution patterns, that, in part may be explained by subtle differences in biological responses in the lung.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.