Abstract

PET/CT using 68Ga-labeled somatostatin analogs (SSA) targeting somatostatin receptors (SSR) on the cell surface of well-differentiated neuroendocrine tumors (NET) represents the clinical reference standard for imaging. However, economic and logistic challenges of the 68Ge/68Ga generator-based approach have disadvantages over 18F-labeled compounds. Here, we present the first in-human data of 18F-SiFAlin-TATE, a novel 18F-labeled, SSR-targeting peptide. The aim was to compare the intra-individual biodistribution, tumor uptake, and image quality of 18F-SiFAlin-TATE to the clinical reference standard 68Ga-DOTA-TOC. Thirteen patients with NET staged with both 68Ga-DOTA-TOC and 18F-SiFAlin-TATE PET/CT have been included in this retrospective analysis. We compared the biodistribution in normal organs and tumor uptake of NET lesions by SUVmean and SUVmax measurement for tracers. Additionally mean and max tumor-to-liver (TLR) and tumor-to-spleen ratios (TSR) have been calculated by division of SUVmean and SUVmax of tumor lesions by the SUVmean of the liver and spleen, respectively. Additionally, image quality was visually rated by 5 blinded readers and an intra-class correlation (ICC) analysis on inter-observer agreement has been performed. Compared with 68Ga-DOTA-TOC, the biodistribution of 18F-SiFAlin-TATE showed somewhat higher, however, statistically not significant higher uptake in the liver, spleen, and adrenal glands. Significantly higher uptake was observed in the kidneys. Tumor uptake was higher in most tumor lesions with significantly higher uptake in common metastatic sites of NET including the liver (SUVmax 18.8 ± 8.4 vs. 12.8 ± 5.6; p < 0.001), lymph nodes (SUVmax 23.8 ± 20.7 vs. 17.4 ± 16.1; p < 0.001) and bone (SUVmax 16.0 ± 10.1 vs. 10.3 ± 5.7; p < 0.01) for 18F-SiFAlin-TATE. The high tumor uptake resulted in favorable TLR and TSR, comparable with that of 68Ga-DOTA-TOC. The ICC analysis on the inter-observer agreement on image quality was substantial and almost perfect. Image quality was rated as excellent in most cases in both 68Ga-DOTA-TOC and 18F-SiFAlin-TATE PET. The favorable characteristics of 18F-SiFAlin-TATE with a high image quality, the kit-like labeling procedure, and the promising clinical performance enable improved logistics and diagnostic possibilities for PET imaging of NET. Our first clinical results warrant further systematic studies investigating the clinical use of 18F-SiFAlin-TATE in NET patients.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call