Abstract
Polychlorinated biphenyls (PCBs) cause many significant ecological problems because of their low degradability, high harmfulness, and solid bioaccumulation.Two bacterial strains were isolated from soil that had been polluted with electrical transformer liquid for more than 40 years. The isolates were distinguished as Lysinibacillus macrolides DSM54Tand Bacillus firmus NBRC15306Tthrough 16S rRNA sequencing analysis.This is the primary report of an agent of the genus Bacillus firmus equipped for the removal of PCBs. The strains could develop broadly on 2-Chlorobiphenyl and 2,4-dichlorobiphenyl. GC/MS analysis of individual congeners revealed up to 80% degradation of the xenobiotics in 96h, attendant with cell proliferation of up to two orders of extent. More extensive investigation of the isolates may be helpful in surveying detoxification forms and in planning bioremediation and bioaugmentation strategies.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.