Abstract

Nowadays, the most commonly used fixation systems are non-resorbable, but new resorbable magnesium alloy fixation screws have been introduced recently. Therefore, the aim of this study was to compare the magnesium fixation screw and the commonly used non-resorbable titanium screw in an animal model. Four 3-wall defect sites were covered with collagen membranes in the mandible of twenty beagle dogs (two sites on the left and two on the right). Each membrane was fixed with either four magnesium screws or four titanium screws. Post-operative follow-up revealed the expected observations such as transient inflammation and pain. Both groups showed a good healing response, with no differences between groups. Micro-CT analysis showed no significant difference between groups in terms of BV/TV or soft tissue volume. The void volume in the magnesium fixation screw group continued to decrease on average between the different timepoints, but not significantly. Furthermore, a gradual progression of the degradation process of the magnesium screws was observed in the same group. Magnesium screws and titanium screws showed equal performance in tissue regeneration according to GBR principles. An additional advantage of magnesium screws is their resorbable nature, which eliminates the need for a second surgical step to remove the screws.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.