We have developed biochemical field effect devices with nano-pillar array structure on the gate. The pH responses of the field effect device with nano-pillar structure were nonlinear. It seems that the plasma treatment of the Si3N4 surface as well as a mixed composition of Si3N4 and SiO2 may play an important role for the nonlinearity of the pH response. Oligonucleotide probes with fluorescent label were immobilized on the surface of the nano-pillar gate structure. The fluorescent intensity of the device with nano-pillar structure was stronger than that of the flat gate device. The increase of the fluorescent intensity for the nano-pillar device could be explained by the increase of the number of immobilized oligonucreotide probes because of the larger surface area. We can therefore expect highly sensitive detection of biomolecules with the nano-pillar gate field effect devices.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.