Abstract

A bioassay method was developed to measure the average intensity within a UV disinfection reactor. The survival of spores of Bacillus subtilis was determined as a function of UV dose to prepare a standard curve. Spores were added to unknown systems, and the survival rate was used to determine the average intensity. A modification was used for flow-through reactors by which spores were injected as a spike and collected at a known time after injection. A point source summation method for calculating intensity was verified by bioassay measurements in a simple cylinder. This calculation method was also applied to multiple-lamp reactors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.