Abstract

An accurate, rapid and simple reversed-phase high performance liquid chromatography (RP-HPLC) bioanalytical method was developed for estimation of Azelnidipine (AZP) and Olmesartan medoxomil (OLM)in human plasma. The AZP, OLM and internal standard (IS) were extracted by liquid-liquid extraction technique. Chromatographic separation was accomplished using BDS Hypersil C18, 250 mm X 4.6 mm, 5µ analytical column. The mobile phase consisted of Acetonitrile: Water, pH adjusted with ortho-phosphoric acid in the ratio 60:40 with flow rate of 1ml/min. Detection and quantification were performed by UV detector at 256 nm. The retention times were found to be 10.05±0.02, 4.3±0.02 and 6.9±0.02 for AZP, OLM and IS respectively. The linearity range was found to be 0.5 to 12 µg /ml and 1 to 15 µg /ml for AZP and OLM respectively.The method was validated as per CDER guideline, was found to be suitable for analysis in biological fluid.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call