Abstract

What is the central question of this study? Is blood flow regulation to hypoxia different between the internal carotid arteries (ICAs) and vertebral arteries (VAs), and what is the measurement error in unilateral extracranial artery assessments compared to bilateral? What is the main finding and its importance? ICA and VA blood flow regulation to hypoxia is comparable when factoring for vessel type and vessel side. Compared to bilateral assessment, vessels assessed unilaterally had individual measurement errors of up to 37%. Assessing the vessel with the larger resting blood flow, not the left or right vessel, reduces unilateral measurement error. Whether blood flow regulation to hypoxia is similar between left and right internal carotid arteries (ICAs) and vertebral arteries (VAs) is unclear. Extracranial blood flow is regularly calculated by doubling a unilateral assessment; however, lateral artery differences may lead to measurement error. This study aimed to determine extracranial blood flow regulation to hypoxia when factoring for vessel type (ICAs or VAs) and vessel side (left or right) effects, and to investigate unilateral assessment measurement error compared to bilateral assessment. In a repeated-measures crossover design, extracranial arteries of 44 participants were assessed bilaterally by duplex ultrasound during 90min of normoxic and poikilocapnic hypoxic (12.0% fraction of inspired oxygen) conditions. Linear mixed model analyses revealed no Condition × Vessel Type × Vessel Side interaction for blood flow, vessel diameter and flow velocity (all P>0.05) indicating left and right ICA and VA blood flow regulation to hypoxia was similar. Bilateral hypoxic reactivity was comparable (ICAs, 1.4 (1.0) vs. VAs, 1.7 (1.1) Δ%·Δ -1 ; P=0.12). Compared to bilateral assessment, unilateral mean measurement error of the relative blood flow response to hypoxia was up to 5%, but individual errors reached 37% and were greatest in ICAs and VAs with the smaller resting blood flow due to a ratio-scaling problem. In conclusion, left and right ICA and VA regulation to hypoxia is comparable when factoring for vessel type and vessel side. Assessing the ICA and VA vessels with the larger resting blood flow, not the left or right vessel, reduces unilateral measurement error.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.