Abstract
This report describes the results obtained from a NML(Ireland)–BIPM bilateral comparison of 1 Ω resistance standards in 2008. The comparison was carried out in the framework of the BIPM ongoing key comparison BIPM.EM-K13.a. Two BIPM 1 Ω travelling standards of CSIRO type were calibrated first at the BIPM, then at the NMLI and again at the BIPM after their return. The stability of the transfer standard was such that the uncertainty associated with the transfer was significantly smaller than the uncertainty arising from the calibrations. The NMLI and the BIPM calibrations were found to be in good agreement, with a mean difference smaller than the expanded uncertainty (k = 2) of the comparison.Main text.To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.