Abstract
The collimator is an essential part of the fiber optic rotary joint design. This study proposes the Large-Beam Fiber Collimator (LBFC) with a double collimating lens and a Thermally Expanded Core (TEC) fiber structure. The transmission model is constructed based on the defocusing telescope structure. The effects of TEC fiber's mode field diameter (MFD) on the coupling loss are investigated by deriving the loss function for the influence of collimator mismatch error and implementing it on a fiber Bragg grating temperature sensing system. The experimental results show that the coupling loss decreases with the increase of the MFD of TEC fiber, while the coupling loss is less than 1dB when the mode field diameter is greater than 14µm. TEC fibers can reduce the effect of angular deviation. Considering the coupling efficiency and deviation, the preferred mode field diameter for the collimator is 20µm. The proposed LBFC enables bidirectional transmission of optical signals for temperature measurement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.