Abstract
Accelerated test techniques are needed in order to qualify bipolar devices intended for use in low dose rate environments. Indeed, low dose rate is known to enhance degradation of bipolar devices. Moreover, the bias of microcircuits is known to play a significant role in device degradation. In this work, bipolar microcircuits are irradiated with different bias configurations during the irradiation. It is shown that the bias configuration leading to the worst-case degradation is dose-rate dependent. Moreover, if a time-saving evaluation technique based on dose-rate switching is to be used, the effect of bias has to investigated. Good agreement is found between the predictive curve obtained with the switched dose-rate technique and the low dose rate data.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.