Abstract

In the past, betatron tune measurements at the Rapid Cycling Synchrotron (RCS) were made using a spectrum analyzer for betatron frequency analysis and one of the extraction kicker magnets to induce the coherent betatron motion. This method had several severe limitations: poor signal-to-noise ratio, inability to extract the beam after the measurement and dependence on the horizontal kick coupling into the vertical plane for vertical tune measurements. A new system is presently being constructed which will eliminate these problems. The beam will be kicked by independent horizontal and vertical ferrite pinger magnets. The beam positron data will be digitized and then analyzed by an array-processing computer using the Fast Fourier Transform (FFT). The control system will allow for additional improvements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.