Abstract

Background and aims: Biophysical evaluation of fetal profile and movements is a useful tool for assessing fetal health, which even has significant effects on neonatal health. This study aimed to compare the biophysical parameters of the profile – fetal movement index, in particular – before and after corticosteroid administration in two groups receiving dexamethasone and betamethasone. Methods: In this descriptive/analytical study, 200 patients diagnosed with preterm delivery and admitted to the gynecology section of Hajar Hospital in Shahrekord in 2016 were investigated. Their demographic findings and medical histories were collected using a checklist form. Then their biophysical profiles 24 to 48 hours after corticosteroid administration were assessed. Finally, the data were analyzed by SPSS v. 18 software using t test, chi-square and Fisher exact test. Results: According to our study results, there was a significant difference in fetal movements before and after receiving corticosteroids, and the decrease in the percentage of movements was greater in the betamethasone group (P<0.001). Also, the biophysical profile was significantly different in the dexamethasone group compared to the betamethasone group (P<0.001). No significant difference was found between two groups in terms of fetal respiration and non-stress test (NST) before and after receiving corticosteroids (P=0.47 and P=0.65, respectively). Conclusion: Dexamethasone administration had less effect on reducing fetal movement index than betamethasone administration. As the result, the biophysical profile was significantly different in the dexamethasone group compared to the betamethasone one.

Highlights

  • The rate of premature births before normal gestational age has recently increased among pregnant women [1]

  • Biophysical profile assessment is a useful tool for assessing fetal health; several studies have recommended performing a comparison between betamethasone and dexamethasone in order for reducing maternal and neonatal complications [12]

  • A significant difference was observed between the two groups receiving betamethasone and dexamethasone in terms of fetal movement (P < 0.001)

Read more

Summary

Introduction

The rate of premature births before normal gestational age (i.e., from 20 to 37 weeks gestation) has recently increased among pregnant women [1] This increase has raised considerable concerns since it can cause numerous problems for both mothers and neonates or infants [2]. This study aimed to compare the biophysical parameters of the profile – fetal movement index, in particular – before and after corticosteroid administration in two groups receiving dexamethasone and betamethasone. Methods: In this descriptive/analytical study, 200 patients diagnosed with preterm delivery and admitted to the gynecology section of Hajar Hospital in Shahrekord in 2016 were investigated. Their demographic findings and medical histories were collected using a checklist form.

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call