Abstract

The current study examines different arrangements of vortex tubes (VTs) to get higher performances for cooling and heating. The effects of thermo-physical parameters such as inlet feed temperature and inlet/outlet vortex tube pressure on generated temperature gradient are investigated. To estimate the cold outlet temperatures, the available equations in the literature are verified against our experimental data. Moreover, we propose a new equation to estimate the hot outlet temperature based on the upper limit of hot temperature (ULHT) and the lower limit of cold temperature (LLCT), verified with experimental data as well. Further, several arrangements are simulated to obtain the minimum cold and the maximum hot temperatures for the outlet streams. Finally, the optimal arrangement of the three vortex tubes and a double-pipe helical heat exchanger that gives the highest performance is proposed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.