Abstract

During endovenous laser ablation (EVLA) of the great saphenous vein, patients often involuntarily mention an uncomfortable "burnt" smell and taste. When applying intense heat to proteins and carbohydrates, it is inevitable that polycyclic aromatic hydrocarbons (PAHs) are formed. This group of PAH includes the human carcinogen benzo[a]pyrene (B[a]P). This study determined the serum concentration of B[a]P just before and after EVLA. A total of 20 patients were included. The B[a]P serum concentration was determined just before and directly after EVLA. In 18 patients, B[a]P was determined before and after EVLA. In 2 patients, EVLA was not possible. In this study, no elevated serum concentration of B[a]P was found before and after EVLA. It remains to be established which heat products cause the burnt smell and taste sensation in patients during EVLA. Further research is needed to determine whether EVLA can be considered as a safe procedure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.