Transcatheter aortic valve implantation (TAVI) has emerged as an alternative treatment for high-risk and inoperable patients. Advanced multimodality imaging, including computed tomography (CT), plays a key role for optimized planning of TAVI. Forty-nine patients (25 women; age, 82.3±8.8 year) with severe aortic stenosis scheduled for TAVI were examined with 128-slice high-pitch dual-source prospective aortoiliac CT angiography (CTA). The 3-coronary-sinus-alignment (3-CSA) plane, comprising left and right anterior oblique and craniocaudal projection, was defined from three-dimensional volume-rendered technique data sets and compared with the intraoperative angiographic plane (deployment plane) used for device implantation. A tolerance level of ±5-degree deviation was acceptable. Volume of intraoperative iodine contrast agent was compared before and after the implementation of the 3-CSA plane estimation by CT. All 49 patients underwent TAVI, during which 6 CoreValves (Medtronic, Minneapolis, MN) and 43 Sapien valves (Edwards Lifesciences, Irvine, CA) were successfully implanted using transapical (n=29), transfemoral (n=17), and transaxillary access (n=4). No severe complications occurred. In 47 patients (96%), CTA correctly predicted the 3-CSA plane used for device implantation. Mean left anterior oblique by CTA was 5.3±6.5 degrees and craniocaudal was -1.3±10.1 degrees. Mean left anterior oblique deviation between CTA and the intraoperative projection was 2.1±2.7 degrees and craniocaudal was 1.7±3.0 degrees. Ostium heights of the right and left coronary arteries were 12±1.9 and 12.9±3.3 mm. No over-stenting occurred in left coronary artery ostia of 8 mm or more. Contrast volume was reduced from 81.8±25.6 to 59.4±40.2 mL (p=0.05) when using 3-CSA plane estimation by CT for final prosthesis implantation plane. Aortoiliac high-pitch 128-slice dual-source CT contributes to TAVI planning, including reliable prediction of the 3-CSA valve deployment plane, which saves contrast volume during the procedure and may facilitate correct valve placement.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.