Abstract

A comparison of dynamic results of a multi-echo contrast-enhanced perfusion study obtained from a keyhole imaging experiment and the results from low-resolution updates is presented. If, for each dynamic state, a separate reference image exists, high spatial resolution in the dynamic results can be preserved through keyhole imaging. If only one reference image can be used, the dynamic key-hole results still offer high spatial frequency content due to spatial phase discontinuities in the images. These often exist at the outline of organs and result from the fat in connective tissues. If the basic assumption of keyhole imaging, namely, that the relevant information is centered in k-space, is violated, as in T2*-weighted gradient-echo images, keyhole imaging can lead to erroneous results even though the update images themselves seem to be free of any artifacts.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.