Abstract

A novel sandwich element design consisting of two facings made of carbon reinforced Textile Reinforced Concrete (TRC), a low density foamed concrete (FC) core and glass fibre reinforced polymer (GFRP) connecting devices was experimentally investigated according to quasi-static and cyclic quasi-static four-point bending. Optical measurements based on Digital Image Correlation (DIC) were taken during testing to enable a detailed analysis of the bending behaviour and level of composite action. A model, verified by the experiments, was developed based on non-linear finite element analysis (NLFEA) to gain further insight on the failure mechanisms. Under both loading conditions, the bending behaviour of the TRC-FC composite elements was characterized by favourable load bearing capacity, partial composite action, superior ductility and multiple fine cracking. The connecting devices were found to be the critical elements causing the initial failure mechanism in the form of localized pull-out within an element.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.