Abstract
Abstract A bench-top apparatus was designed and built to investigate factors that affect dust generation. The apparatus allows the investigation of process variables, material properties, and the size distribution of generated dust, thus addressing the limitations of other bench-top dustiness testers. The controlled testing of hazardous materials is also possible in this air-tight device. The apparatus consists of a dust generation section and a dust measurement section. Materials are introduced to the generation section at various drop heights and flows by an injection slide. Dust is generated by the impact of the falling material and the release of air entrained with the falling stream of material. The generated dust is drawn through an elutriator, which removes particles 25 μm and greater in aerodynamic diameter. The size distribution of the residual dust is measured for particles between 1.4 and 15 μm in aerodynamic diameter with a cascade impactor. The effects of material drop height, mass flow, and ...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.