Abstract

Stereotactic radiosurgery treatment delivery can be performed with a range of devices, each of which have evolved over recent years. We sought to evaluate the differences in performance of contemporary stereotactic radiosurgery platforms and also to compare them with earlier platform iterations from a previous benchmarking study. The following platforms were selected as "state of the art" in 2022: Gamma Knife Icon (GK), CyberKnife S7 (CK), Brainlab Elements (Elekta VersaHD and Varian TrueBeam), Varian Edge with HyperArc (HA), and Zap-X. Six benchmarking cases were used from a 2016 study. To reflect the evolution of increasing numbers of metastases treated per patient, a 14-target case was added. The 28 targets among the 7 patients ranged from 0.02 to 7.2 cc in volume. Participating centers were sent images and contours for each patient and asked to plan them to the best of their ability. Although some variation in local practice was allowed (eg, margins), groups were asked to prescribe a specified dose to each target and tolerance doses to organs at risk were agreed upon. Parameters compared included coverage, selectivity, Paddick conformity index, gradient index (GI), R50%, efficiency index, doses to organs at risk, and planning and treatment times. Mean coverage for all targets ranged from 98.2% (Brainlab/Elekta) to 99.7% (HA-6X). Paddick conformity index values ranged from 0.722 (Zap-X) to 0.894 (CK). GI ranged from a mean of 3.52 (GK), representing the steepest dose gradient, to 5.08 (HA-10X). The GI appeared to follow a trend with beam energy, with the lowest values from the lower energy platforms (GK, 1.25 MeV; Zap-X, 3 MV) and the highest value from the highest energy (HA-10X). Mean R50% values ranged from 4.48 (GK) to 5.98 (HA-10X). Treatment times were lowest for C-arm linear accelerators. Compared with earlier studies, newer equipment appears to deliver higher quality treatments. CyberKnife and linear accelerator platforms appear to give higher conformity whereas lower energy platforms yield a steeper dose gradient.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.