Abstract

The Savannah River National Laboratory (SRNL) results of the 2008 Performance Assessment (PA) (WSRC, 2008) sensitivity/uncertainty analyses conducted for the trenches located in the EArea LowLevel Waste Facility (ELLWF) were subject to review by the United States Department of Energy (U.S. DOE) Low-Level Waste Disposal Facility Federal Review Group (LFRG) (LFRG, 2008). LFRG comments were generally approving of the use of probabilistic modeling in GoldSim to support the quantitative sensitivity analysis. A recommendation was made, however, that the probabilistic models be revised and updated to bolster their defensibility. SRS committed to addressing those comments and, in response, contracted with Neptune and Company to rewrite the three GoldSim models. The initial portion of this work, development of Slit Trench (ST), Engineered Trench (ET) and Components-in-Grout (CIG) trench GoldSim models, has been completed. The work described in this report utilizes these revised models to test and evaluate the results against the 2008 PORFLOW model results. This was accomplished by first performing a rigorous code-to-code comparison of the PORFLOW and GoldSim codes and then performing a deterministic comparison of the two-dimensional (2D) unsaturated zone and three-dimensional (3D) saturated zone PORFLOW Slit Trench models against results from the one-dimensional (1D) GoldSim Slit Trench model.more » The results of the code-to-code comparison indicate that when the mechanisms of radioactive decay, partitioning of contaminants between solid and fluid, implementation of specific boundary conditions and the imposition of solubility controls were all tested using identical flow fields, that GoldSim and PORFLOW produce nearly identical results. It is also noted that GoldSim has an advantage over PORFLOW in that it simulates all radionuclides simultaneously - thus avoiding a potential problem as demonstrated in the Case Study (see Section 2.6). Hence, it was concluded that the follow-on work using GoldSim to develop 1D equivalent models of the PORFLOW multi-dimensional models was justified. The comparison of GoldSim 1D equivalent models to PORFLOW multi-dimensional models was made at two locations in the model domains - at the unsaturated-saturated zone interface and at the 100m point of compliance. PORFLOW model results from the 2008 PA were utilized to investigate the comparison. By making iterative adjustments to certain water flux terms in the GoldSim models it was possible to produce contaminant mass fluxes and water concentrations that were highly similar to the PORFLOW model results at the two locations where comparisons were made. Based on the ability of the GoldSim 1D trench models to produce mass flux and concentration curves that are sufficiently similar to multi-dimensional PORFLOW models for all of the evaluated radionuclides and their progeny, it is concluded that the use of the GoldSim 1D equivalent Slit and Engineered trenches models for further probabilistic sensitivity and uncertainty analysis of ELLWF trench units is justified. A revision to the original report was undertaken to correct mislabeling on the y-axes of the compliance point concentration graphs, to modify the terminology used to define the ''blended'' source term Case for the saturated zone to make it consistent with terminology used in the 2008 PA, and to make a more definitive statement regarding the justification of the use of the GoldSim 1D equivalent trench models for follow-on probabilistic sensitivity and uncertainty analysis.« less

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.